ROOF TESTING
TAS 106 - TILE UPLIFT TEST This is a product application control test to confirm the following: A) Sufficient bonding by the mortar or adhesive to the tile and underlayment in a mortar or adhesive set tile system. B) Or an effective mechanical attachment of components within a rigid discontinuous roof.
TAS 126 - INFRARED/ IMPEDANCE MOISTURE SURVEY This is a non destructive testing for the resistance of moisture, and the subsequent destructive testing by means of core cuts to confirm moisture content in roof system assembly.
TAS 105- FASTENER PULL TEST This is a withdrawal resistance testing of fasteners used to for attachment of various components to various substrate materials. In most cases this fasteners test is required prior to obtaining a roof permit for nailable decks such as, lightweight insulating concrete, gypsum, wood fiber (Tectum), etc.
ASBESTOS SURVEY On all commercial re-roofing, this test is mandatory prior to obtaining a roofing permit. There are generally two types of asbestos found on most roofs: Friable and Non-friable.
ORDER NOW ORDER NOW ORDER NOW ORDER NOW ORDER NOW ORDER NOW CALL FOR QUOTE CALL FOR QUOTE
TAS 124 - BELL/BONDED PULL TEST This test is used to determined the resistance uplift pressure of newly installed or existing, fully adhered, built-up, bituminous roofing systems over mechanically attached or adhered rigid board insulation over various deck types. Making sure that the existing or new roof meets the wind pressures should be of major concern to all parties involved.
ORDER NOW ORDER NOW
© Florida TEC Management Services. Inc. 2017
14104 SW 163 ST Miami FL, 33177
305.256.4550
Got Questions?
ROOF TESTING
TAS 106 - TILE UPLIFT TEST This is a product application control test to confirm the following: A) Sufficient bonding by the mortar or adhesive to the tile and underlayment in a mortar or adhesive set tile system. B) Or an effective mechanical attachment of components within a rigid discontinuous roof.
TAS 105- FASTENER PULL TEST This is a withdrawal resistance testing of fasteners used to for attachment of various components to various substrate materials. In most cases this fasteners test is required prior to obtaining a roof permit for nailable decks such as, lightweight insulating concrete, gypsum, wood fiber (Tectum), etc.
ASBESTOS SURVEY On all commercial re-roofing, this test is mandatory prior to obtaining a roofing permit. There are generally two types of asbestos found on most roofs: Friable and
ORDER NOW ORDER NOW ORDER NOW ORDER NOW CALL FOR QUOTE CALL FOR QUOTE